по минимальному стандарту, lactation rooms are to contain: *equipment - (1) sink with cold/hot water faucet; (1) refrigerator (could be undercounter); (1) arm- or lounge-chair; (1) table or counter surface of minimum 2'x 2'. *interior area should be min 50sf, to accommodate ADA-compliant wheelchair' maneuvering circle of 60" and maintain 4'-6" clear in front of swing-in door *power requirements:(1) dedicated quad (for breast pump, vacuum cleaner, humidifier, refrigerator) * HVAC requirements: separate branch to be controlled by room-located (1) thermostat * noise reduction requirements: partitions (walls) are to be state-approved acoustic type (to be extended to structure, not to suspended ceiling, contain acoustic insulation and sealant at floor and ceiling joints) -door should be lockable from inside, with lever-type lockset -finishes and furnishings to be Class A (II) fire-code compliant -lighting level to be of min 45CA; if there is a window there must be a matte shade or curtain, operable from inside
как вы думаете, орлица вы наша, сколько всё это стОит? PS комнату лактации запрещается совмещать с туалетной комнатой.
no subject
Date: 2020-01-01 10:30 pm (UTC)вы, конечно, знаете лучше архитектора, кот. проектирует коммерческие интерьеры так чтоб удовлетворяли законам и стандартам штатов.
нет, птичка.
по минимальному стандарту, lactation rooms are to contain:
*equipment - (1) sink with cold/hot water faucet; (1) refrigerator (could be undercounter); (1) arm- or lounge-chair; (1) table or counter surface of minimum 2'x 2'.
*interior area should be min 50sf, to accommodate ADA-compliant wheelchair' maneuvering circle of 60" and maintain 4'-6" clear in front of swing-in door
*power requirements:(1) dedicated quad (for breast pump, vacuum cleaner, humidifier, refrigerator)
* HVAC requirements: separate branch to be controlled by room-located (1) thermostat
* noise reduction requirements: partitions (walls) are to be state-approved acoustic type (to be extended to structure, not to suspended ceiling, contain acoustic insulation and sealant at floor and ceiling joints)
-door should be lockable from inside, with lever-type lockset
-finishes and furnishings to be Class A (II) fire-code compliant
-lighting level to be of min 45CA; if there is a window there must be a matte shade or curtain, operable from inside